Navigation:SATA TECHNOLOGY CO., LTD >>Product >> Flammability Test Equipments >> ST-7602L Halogen Release measurement Device
Product

ST-7602L Halogen Release measurement Device

Introduction

ST-7602L Halogen Release measurement Device

Product Details

ST-7602L Halogen Release measurement Device

 
Standard: According to GB/T17650.1-1998, GB/T17650.2-1998, IEC60754-1:1994, IEC60754-2:1991, GB/T19666-2005, GA306.1-2007, GA306.2-2007, UL2556-2007.
Scope: Applies to determine total quantity of halogen-free and low halogen flame retardant cable’s halogen acid gas and measure PH value and conductivity to determine the acidity gas,
Main parameter:
1.      Quartz material tubular furnace heating furnace chamber size: L600mm×ф42mm;
2.      Tubular furnace input power: 220V/3.8KW;
3.      Inner diameter of quartz tube: ф34±1mm;
4.      According to inner diameter of quartz tube gas flow-meter calculate the setting flux:
ρ=V·πD2/4=20*3.14*342 /4ml/h=302ml/min±10%;
5. Accessories: pH meter and conductivity analyzer one for each, 500mL gas washing and absorbing device and connection head.

  • ©Copyright@SATA TECHNOLOGY CO., LTD
  • Tel:+86 769 83814636 FAX:+86 769 83509758
  • Address:Changping Town, Dongguan City, Guangdong Province, China 523560
Keywords:Halogen Release measurement Device, pH Testing device, Halogen and pH Test Device